Function
- Variable orifice, restrictive type, hydraulic flow control, non-pressure compensated. Pressure balanced, bidirectional flow.
- 90 degree rotation
- Can be used with most of our standard Motorized Flow Control manifold packages
Operating Pressure
- 3000 psi maximum differential
Consult factory for higher operating pressures
Flow Ranges
Based on 100 PSI pressure differential with valve fully open. See pressure drop curves for additional application data
- 15 = 0-15 gpm (Equivalent to Ø.25” orifice at full open)
- 20 = 0-20 gpm (Equivalent to Ø.35” orifice at full open)
- 35 = 0-35 gpm (Equivalent to Ø.49” orifice at full open)
- 50 = 0-50 gpm (Equivalent to Ø.56” orifice at full open)
Custom ranges are available upon request
Construction
- Cage, Body and Spool: Steel, exposed parts plated
- Motor housing assembly: Anodized aluminum
- Standard line bodies are aluminum
Steel bodies are available upon request
Seal Material
- Buna N and polyurethane standard
Viton or EPR optional
Internal Leakage
- 5 cubic inch per minute per 1000 psi
Temperature
- -40 to 120°C
Cavity
- C 16-2 industry common cavity
Valve Installation Torque
- 65 ft-lbs
Cartridge Weight
- H16 cartridge only 1.2 lbs
- H16 with aluminum body 4.1 lbs
Seal kit
- SFP25249
How To Build Your Part Number
Example: H165010183
H16 = Motorized flow control, 16-2 cavity size
50 = Flow range – gallons per minute (gpm) at full open and 100 psi pressure differential. Select one of the following:
- 15 = 0-15 gpm
- 20 = 0-20 gpm
- 35 = 0-35 gpm
- 50 = 0-50 gpm
10183 = line body manifold
- 10183 = SAE-12 ports
- 10183LS = SAE-16 ports and SAE-4 LS port