Function
- Variable orifice, restrictive type, hydraulic flow control, non-pressure compensated. Pressure balanced, bidirectional flow.
- 90 degree rotation
- Can be used with most of our standard Motorized Flow Control manifold packages
Operating Pressure
- 3000 psi maximum differential
Consult factory for higher operating pressures
Flow Ranges
Based on 100 PSI pressure differential with valve fully open. See pressure drop curves for additional application data
- 080 = 0-80 gpm (Equivalent to Ø.55” orifice at full open)
- 100 = 0-100 gpm (Equivalent to Ø.60” orifice at full open)
- 120 = 0-120 gpm (Equivalent to Ø.66” orifice at full open)
Custom ranges are available upon request
Construction
- Cage, Body and Spool: Steel, exposed parts plated
- Motor housing assembly: Anodized aluminum
- Standard line bodies are aluminum
Steel bodies are available upon request
Seal Material
- Buna N and polyurethane standard
Viton or EPR optional
Internal Leakage
- 15 cubic inch per minute per 1000 psi
Temperature
- -40 to 120°C
Cavity
- C 20-2 industry common cavity
Valve Installation Torque
- 80 ft-lbs
Cartridge Weight
- H20 cartridge only 1.6 lbs
- H20 with aluminum body 4.9 lbs
Seal kit
- SFP25673
How To Build Your Part Number
Example: H2012010184
H20 = Motorized flow control, 20-2 cavity size
120 = Flow range – gallons per minute (gpm) at full open and 100 psi pressure differential. Select one of the following:
- 080 = 0-80 gpm
- 100 = 0-100 gpm
- 120 = 0-120 gpm
10184 = line body manifold
- 10184 = SAE-16 ports
- 10184LS = SAE-20 ports and SAE-4 LS port