Function

  • Motor driven, variable orifice, restrictive type, hydraulic flow control, non-pressure compensated. Pressure balanced, bi-directional flow.

Operating Pressure

    • 3000 psi maximum differential
      Consult factory for higher operating pressures

Flow Ranges

Based on 100 PSI pressure differential with valve fully open. See pressure drop curves for additional application data

    • 03 = 0-3 gpm (Equivalent to Ø.14” orifice at full open)
    • 05 = 0-5 gpm (Equivalent to Ø.18” orifice at full open)
    • 10 = 0-10 gpm (Equivalent to Ø.25” orifice at full open)
    • 15 = 0-15 gpm (Equivalent to Ø.31” orifice at full open)
      Custom ranges are available upon request

Voltage

  • 12 & 24 VDC

Construction

  • Cage, Body and Spool: Steel, exposed parts plated
  • Motor housing assembly: Anodized aluminum

Seal Material

    • Buna N and polyurethane standard
      Viton or EPR optional

Current Draw

  • 0.8 amp when powered at 12 volts
  • 1.0 amp when powered at 24 volts

Internal Leakage

  • 1 cubic inch per minute per 1000 psi

Temperature

  • -40 to 120°C

Operating Speed

  • 1-48 seconds, See appendix page 1 for details

Cavity

  • Sun T-13A

Valve Installation Torque

  • 35 ft-lbs

Cartridge Weight

  • F13A cartridge only = 2.5 lbs

Seal Kit

  • SFP25674
F13A

How To Build Your Part Number

Example: F13A15EWPT
F13A = Motorized flow control, Sun T-13A cavity size
15 = Flow range – gallons per minute (gpm) at full open and 100 psi pressure differential. Select one of the following:

  • 03 = 0-3 gpm
  • 05 = 0-5 gpm
  • 10 = 0-10 gpm
  • 15 = 0-15 gpm

E = Operating Speed, 7 seconds full travel operating speed. Select letter code from appendix 1
WPT = Options: Connector type. See appendix 2 for available options

Download Files

F13A Spec Sheet (printable PDF)